Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors
DOI: https://doi.org/10.1016/j.jbiomech.2019.109424
In: Journal of Biomechanics
Hyaluronan supplementation as a mechanical regulator of cartilage tissue development under joint-kinematic-mimicking loading
DOI: https://doi.org/10.1098/rsif.2017.0255
In: Journal of the Royal Society Interface
Determining 3D Kinematics of the hip using video fluoroscopy: Guidelines for balancing radiation dose and registration accuracy
DOI: https://doi.org/10.1016/j.arth.2017.05.036
In: Journal of Arthroplasty
Surface and subsurface changes as a result of tribocorrosion at the stem-neck interface of bi-modular prosthesis
DOI: https://doi.org/10.1016/j.biotri.2017.02.002
In: Biotribology
SiNx Coatings Deposited by Reactive High Power Impulse Magnetron Sputtering: Process Parameters influencing the Residual Coating Stress
DOI: 10.1063/1.4977812
In: Journal of Applied Physics
Influence of substrate heating and nitrogen flow on the composition, morphological and mechanical properties of SiNx coatings aimed for joint replacements
DOI: 10.3390/ma10020173
In: Materials 2017
The effect of cyclic load on the evolution of fretting current at the interface of Metal-on-Metal and Ceramic-on-Metal taper junction of hip prostheses
In: Bone and Joint Journal
Size- and dose-dependent reduction of oxidative stress in L929 fibroblasts by silicon nitride particles
In: Bone & Joint Surgery
Development of a novel method for silicon nitride wear debris retrieval from periprosthetic tissue in low wearing systems
In: Bone & Joint Surgery
Corrosion of the head-stem taper junction – are we on the verge of an epidemic?
DOI: https://doi.org/10.1007/s11420-016-9526-4
In: HSS Journal: The Musculoskeletal Journal of Hospital for Special Surgery
Determining 3D Kinematics of the Hip Using Video Fluoroscopy: Guidelines for Balancing Radiation Dose and Registration Accuracy
DOI: https://doi.org/10.1016/j.arth.2017.05.036
In: The Journal of Arthroplasty
SiNx Coatings Deposited by Reactive High Power Impulse Magnetron Sputtering: Process Parameters influencing the Nitrogen content
DOI: https://doi.org/10.1021/acsami.6b05830
Kinematic differences in patients with unilateral and bilateral total hip replacements
In: 22nd Congress of the European Society of Biomechanics
Influence of body segment parameter uncertainty on joint loading during gait
In: 22nd Congress of the European Society of Biomechanics
Basic Biomechanics of the Hip
DOI: http://dx.doi.org/10.1016/j.mporth.2016.04.014
In: Orthopaedics and Trauma Journal
The influence of surgical approach on outcomes of total hip arthroplasty
DOI: https://doi.org/10.1016/j.mporth.2016.05.006
A comprehensive assessment of biological responses to silicon nitride nanoparticles and cobalt chromium wear debris from total hip replacements
DOI: https://doi.org/10.3389/conf.FBIOE.2016.01.02591
In: Frontiers Media
A New Method for Isolation of Ceramic Nano Particles from Serum Lubricants under Very Low Wearing Conditions,
DOI: https://doi.org/10.1016/j.actbio.2016.07.004
In: Elsevier Ltd.
Influence of cartilage surface topography on intra-articular flow
DOI: https://www.tandfonline.com/doi/full/10.1080/10255842.2016.1215438
In: Computer Methods in Biomechanics and Biomedical Engineering
Explosive and maximal strength before and 6 months after total hip arthroplasty
DOI: 10.1002/jor.23626
The taper corrosion pattern observed for one bi-modular stem design is related to geometry-determined taper mechanics
DOI: http://dx.doi.org/10.1016/j.medengphy.2017.06.003
In: ELSEVIER
The influence of nitrogen content and substrate temperature on the hardness and Young’s modulus of silicon nitride coatings for joint implants
In: CORS 2013
A mechanical wear model of metal-on-metal total hip replacements in mixed lubrication conditions
In: CIST 2014 (7th China International Symposium on Tribology) Xuzhou China, 28-30 April 2014
Predictive Wear Modelling of the Articulating Metal-on-Metal Hip Replacements
DOI: 10.1002/jbm.b.33568 to be published in 2016
A numerical study of non-Newtonian transient elastohydrodynamic lubrication of metal-on-metal hip prostheses
DOI: 10.1016/j.triboint.2015.03.003 Published January 2016
In: Tribology International (Volume 93, pages 486-494) ISSN: 0301-679X
A numerical study of non-Newtonian transient EHL of metal-on-metal hip prostheses
In: 41th Leeds-Lyon 2014 (2-5 September 2014)
Development and production of Si-compound coatings for long lasting joint replacements
In: Linnaeus seminars, Linköping, Sweden, invited (November 2015)
Development SiNx coatings for joint replacements
In: Advanced Functional Materials (AFM) meeting, Linköping, Sweden, invited (October 2015)
SiyNx coatings for enhanced joint life time
In: Agora Materiae seminars, Linköping, Sweden, invited (March 2015)
Primary hip replacement stem taper fracture due to corrosion in 3 patients
DOI: 10.3109/17453674.2015.1128780 Published: 11 January 2016
In: Acta Orthopaedica, Taylor & Francis
A Novel Method for Isolation and Recovery of Ceramic Nanoparticles and Metal Wear Debris from Serum Lubricants at Ultra-low Wear Rates
DOI: 10.1016/j.actbio.2016.07.004
In: Acta biomaterialia 42 · July 2016
Stoichiometric silicon oxynitride thin films reactively sputtered in Ar/N2O plasmas by HiPIMS
In: Journal of Physics D: Applied Physics
Lower extremity muscle weakness in patients with symptomatic hip osteoarthritis.
In: 75th Annual Congress of the Swiss Society of Orthopaedics and Traumatology (SGOT), Basel, Switzerland, 24. – 26.06.2015
Lower limb muscle weakness in patients with symptomatic hip osteoarthritis.
In: 20th Annual Congress of the European College of Sport Science (ECSS), Malmö, Sweden, 24. – 27.06.2015 Book of Abstracts p. 218
Sub-surface investigation of fretted Co28Cr6Mo and Ti6Al4V alloys
In: ISTA 2015 Orthopaedic Proceedings A supplement to The Bone & Joint Journal
Bottoming-out as the ultimate failure mode of the neck taper of a bi-modular THR stem design.
In: ISTA 2015 (International Society for Technology in Arthroplasty) Orthopaedic Proceedings supplement to The Bone & Joint Journal
A Novel Technique for Isolation and Characterisation of Ceramic Nanoparticles and Metal Wear Particles from Hip Simulator Serum Lubricants under Ultra Low Wearing Conditions
In: ISTA 2015 (International Society for Technology in Arthroplasty) Orthopaedic Proceedings supplement to The Bone & Joint Journal
Can cobalt(II) and chromium(III) ions released from joint prostheses influence the friction coefficient?
DOI: 10.1021/acsbiomaterials.5b00183
In: ACS Biomaterials Science and Engineering
Surface and Subsurface Analyses of Metal-on-Polyethylene Total Hip Replacement Retrievals
DOI: 10.1007/s10439-015-1462-9
In: Annals of Biomedical Engineering (work related to LLJ but mainly funded by other sources)
Predicted fluid drag forces at cartilage surfaces during couette flow: Influence of synovial fluid properties
In: Proceedings of the 7th World Congress of Biomechanics, Boston, USA, 7.2014.
Retention of synovial fluid within the intra-articular gap: Influence of synovial fluid properties
In: Proceedings of the 12th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE), Amsterdam, Netherlands, 10.2014
Silicon oxynitride films deposited by reactive high power impulse magnetron sputtering using nitrous oxide as a single-source precursor
DOI: 10.1116/1.4927493
Morphology and dissolution rate of wear debris from silicon nitride coatings – a laboratory investigation
DOI: 10.1021/acsbiomaterials.6b00133
In: ACS Biomaterials Science + Engineering
Quantitative analysis of surface deterioration in retrieved flat male tapers
In: World Congress of Biomechanics, Boston, 2014
Lower limb muscle weakness in patients with symptomatic hip osteoarthritis
In: ECSS 2015, Malmö/SWE
A New Method for Isolation of Ceramic Nanoparticles from Serum Lubricants Under Extremely Low Wearing Conditions
In: ORS
Silicon oxynitride films deposited by reactive high power impulse magnetron sputtering using nitrous oxide as single-source precursor
DOI: 10.1116/1.4927493
In: Journal of Vacuum science and technology
Quantification of material loss from the non-circular neck piece taper of one bi-modular primary hip prosthesis design
DOI: Published 1 Oct 2015
In: The Bone & Joint Journal, (first review resubmitted)
Hydrogenated SiyNx coatings deposited by rHiPIMS using NH3
In: ICMCTF 2015 San Diego CA, USA
Corrosion pattern of the neck-stem taper of a bi-modular total hip arthroplasty design (Rejuvenate)
In: 8th Endoprotheses Congress, Berlin, Feb. 2015
A numerical study of non-Newtonian transient elastohydrodynamic lubrication of metal-on-metal hip prosthesis
DOI: https://doi.org/10.1016/j.triboint.2015.03.003
In: Tribology International (Leeds-Lyon special issue).
Novel Coatings for Reduced Wear and Corrosion in Orthopaedic Bearing Applications (poster)
In: Leeds-Lyon tribology Symposium
Corrosion topology of the neck-stem taper of a bi-modular total hip arthroplasty design (Rejuvenate)
In: ASTM Symposium on Modularity and Tapers in Total Joint Replacement Devices, New Orleans, Nov. 2014
Fretting–Corrosion Regimes and Wear Mechanism of Coupled Co-Cr-Mo and Ti-6Al-4V alloys
In: Tribology – Materials, Surfaces & Interfaces Volume 9, Issue 4, 2015
SiyNx coatings deposited by reactive High Power Impulse Magnetron Sputtering
In: HiPIMS 2014, 5th International Conference on HIPIMS June 2014, Sheffield, UK
Generation and characterization of wear debris from silicon nitride coatings aimed to increase the longevity of joint replacements
In: Bone & Joint Surgery
The influence of nitrogen content and substrate temperature on the hardness and Young’s modulus of silicon nitride coatings for joint implants
In: CORS 2013
Fretting of CoCrMo and Ti6Al4V alloys in modular prostheses
DOI: 10.1179/1751584X15Y.0000000014 Published 20 Jun 2015
Dissolution behaviour of silicon nitride coatings for joint replacements
DOI: 10.1016/j.msec.2016.01.049 Published 22 January 2016
Quantification of material loss from the neck piece taper junctions of a bimodular primary hip prosthesis. A retrieval study from 27 failed Rejuvenate bimodular hip arthroplasties
DOI: 10.1302/0301-620X.97B10.35342 Published 1 October 2015